The simple solution for simple tasks. Optimally matched to requirements in the power range from 0.12 to 0.75 kW (0.16 to 10 HP), the MICROMAS- TER 410 is the low-price solution for 3-phase mo- tors with variable speeds in 1-phase power sys- tems. Its compact design allows fast and prob- lem-free installation and commissioning; this smallest member of the MICROMASTER family can be installed from the side and can therefore find space in the smallest control cabinet. And to top it off, its price-performance ratio is outstan- ding.


Typical uses


Pumps, fans, advertising panels, cabinets, door operating mechanisms, vending machines, packaging machines.

 

MICROMASTER 410 - Technical data Voltage and power ranges
100¨C120 V, ¡À 10%, 1 AC, 0.12 to 0.55 kW (0.16 to 0.75 HP)
200¨C240 V, ¡À 10%, 1 AC, 0.12 to 0.75 kW (0.16 to 1.0 HP)
Operating temperature ¨C10 ¡ãC to +50 ¡ãC
Types of control V/f characteristic, multipoint characteristic (parameterizable V/f characteristic)
Inputs 3 digital inputs, 1 analog input
Outputs 1 relay output
Link-up
to automation The inverter partner for LOGO! and SIMATIC S7-200


Its strengths in brief


¡¤ Its contactor-like design enables a simple, EMC compliant installation with ease of handling
¡¤ Operation with 30-mA r.c.c.b. circuit breaker in conjunction with an inte- grated B class filter variant allows direct use of the inverter in house- hold and industrial applications
¡¤ Fanless cooling but nevertheless compact for noise-sensitive appli- cations
¡¤ For use with 230-V and 115-V single-phase power systems and can therefore be used globally
¡¤ Versatile inputs and outputs facili- tate simple use of the inverter¡¯s universal functionality
¡¤ Various methods of commissioning with an operator panel or SW tool enabling simple set-up according to the wishes of the user
¡¤ Low-cost drive dimensioning due to high overload capability
¡¤ Compound braking for controlled rapid braking
¡¤ Increase in equipment availability due to automatic restart in the event of a power failure or operating fault
¡¤ Minimal stress on motor when inver- ter connected to a rotating motor
¡¤ Various methods of setting the fre- quency setpoint
¡¤ Communication interface (USS) in each inverter offers integration in a net-worked automation system
¡¤ Suitable for use in IT networks thanks to removable ¡°Y¡± capacitor
¡¤ Optional plug-in operator panel


Protective functions


All the necessary protection and overload functions are already integrated as standard features. For example, the fast-acting current limiter (FCL) - the ulti- mate, universal protection mechanism.



     

Address£ºRoom B401-403 Zhonghuan Building Yunlin 31# Hankou District Wuhan City, Hubei Province, PRC
POST Code£º
430015
  TEL£º027-85748477¡¢85745463¡¢85748446
FAX£º  85748477-801  Website£º www.whhenry.com.cn
E-mail£ºhjiang@whhenry.com.cn
Wuhan Henry Automation Engineering Co.,Ltd
@Copyright By Wuhan Henry Automation Engineering Co.,Ltd