Every task performed by a drive system involves
its own specific requirements. There is therefore a demand for inverter
solutions that can be easi- ly and flexibly adapted to cope with the broadest
variety of challenges. It is exactly this flexibility which characterizes
our modular MICROMAS- TER 430. Specially for use with pumps and fans in
industry, it performs a wide variety of tasks in similar applications
as well. Compared to the MICROMASTER 420, it features greater power efficiency
and has more inputs and outputs as well as an optimized operator panel
with switch- over between manual and automatic modes of operation.
Typical uses
Specially suitable for pumps and fans.
|
MICROMASTER
430 - Technical data Voltage andpower ranges
380¨C480 V, ¡À 10%,
3 AC, 7.5 to 250 kW (10 to 300 HP)
Operating temperature ¨C10 ¡ãC to +40 ¡ãC
Process control Internal PID controller
Types of control FCC (Flux Current Control), multipoint characteristic
(parameterizable V/f characteristic), V/f characteristic
Inputs 6 digital inputs, 2 analog inputs, 1 PTC/KTY input
Outputs 2 analog outputs, 3 relay outputs
Link-up
to automation The ideal partner for your automation needs, from connection
to SIMATIC S7-200 to integration in TIA with SIMATIC and SIMOTION.
Its strengths in brief
¡¤ Compact housing
¡¤ Easy to install
¡¤ Guided commissioning
¡¤ Numerous communications options
¡¤ Ability to cope with high starting tor- ques
¡¤ FCC control (Flux Current Control) for high drive quality, even when
load changes occur
¡¤ Integrated activation of up to three additional drives (motor staging)
for low-cost power multiplication for pump and fan drives
¡¤ Bypass support for rapid motor changeover to direct mains opera- tion
for maximum process safety
¡¤ Energy-saving function with motor shut-off for maximum energy saving
without altering the availability of full drive output
¡¤ Dry-running detection for pump drives
¡¤ 3 sets of drive data from which can be selected in order to adapt the
in- verter to different operating circum- stances
¡¤ Compound braking for controlled rapid braking
¡¤ 4 skip frequencies for minimizing stress on pipe networks or on the
load machine when resonance occurs
¡¤ Increase of equipment availability due to automatic restart
¡¤ Minimal stress on motor when inverter connected to rotating motor
¡¤ Evaluation of motor temperature by means of PTC/KTY input for integra-
ted motor protection
¡¤ Prepared for use in IT networks
¡¤ Variants with an integrated EMC filter round off the range of products
and help to reduce the amount of instal- lation work needed.
|